Switchable Hardness Measuring Heads
Shore and IRHD Measuring Heads for Hardness Tester Automatic Hardness Check - Drive



 
With the new generation of Drive Automatic Hardness Testers from Gibitre Instruments, tailor the instrument to your measurement needs. The interchangeable head system lets you swap Shore and IRHD heads on the motorized stand in seconds; the rigid quick coupling preserves perfect perpendicularity, a prerequisite for reliable results on your materials. This versatility suits labs that work across multiple measurement scales without multiplying tools: one hardness tester covers diverse needs, streamlining workflows and cutting setup time between tests.

All measuring heads comply with ISO 48-2, ISO 48-4, ASTM D2240, and ASTM D1415.

Why choose the Drive Automatic Hardness Check? It grows with you: additional heads can be added after purchase, expanding your lab’s measurement capabilities as new requirements emerge and safeguarding your investment. The Drive version’s configurability and rapid head change help you respond quickly to varying demands while maintaining continuity. In short, a

Your Testing Needs 
Do you need to test different products according to a specific hardness scale?
Do you need to evaluate incoming compounds and finished parts across multiple scales?
Do you require the flexibility to switch between various hardness scales without notice?

Whatever your needs, we offer the ideal setup to meet your requirements.

Versatility in One Instrument 
The Universal Support for Automatic Hardness Testers in the Drive version accommodates all available Shore, IRHD, and VLRH hardness units. Swapping measuring heads offers a versatile solution for research centers or labs that require measurements across various scales, as well as for companies that primarily use one scale but need occasional checks against others.



Complete Hardness Testing for Simultaneous Use 
For companies conducting systematic production checks using different measurement scales (e.g., Shore A and Micro-IRHD), dedicated hardness units for each required scale are essential. The optimal setup, based on our experience, involves installing independent hardness testers connected to the same PC. This configuration allows multiple operators to use the instruments simultaneously without any interruptions.

Many instruments in one 
The solid quick coupling system allows the head to be replaced in seconds while ensuring its perfect pependicularity with respect to the support base.

To replace the measuring head:
- Remove the connecting cable
- Unscrew the locking screw
- Replace the head with the desired one
- Screw the locking screw
- Insert the connection cable

The instrument automatically recognizes the applied head and is immediately ready for testing.


Available Hardness Units 
Shore A,
Shore D,
Shore A0,
Shore 00,
Shore AM (micro),
IRHD-Micro,
IRHD-Normal,
IRHD-Hard,
IRHD-Low,
VLRH (Very Low Rubber Hardness).




 

Complete hardness testers for simultaneous use 
For companies that need to perform systematic production checks against several different measurement scales (e.g., Shore A and Micro-IRHD), it is necessary for durometers to be available at the same time to perform measurements at the required scale.
The optimal solution we propose for such cases is the installation of multiple complete hardness testers connected to the same PC with a single software license. In this way the instruments can be used simultaneously and by several operators without any interruption.

Automatic performance of multiple tests on the sample 
International standards require the performance of multiple hardness tests on the specimen and the calculation of the median value.
• The specimen holder plate with motorized rotation allows multiple tests to be performed automatically at different points on the specimen.
• The operator can set the number of tests to be performed automatically on the specimen and the angle of rotation between successive tests.




Accredia Calibration of the hardness units 
Each Hardness Unit can be supplied with an ACCREDIA calibration certificate issued by the Accredia laboratory of Gibitre instruments.
The calibration is carried out according to the Technical Procedure approved by Accredia and in compliance with the requirements of the ISO 48-2 (IRHD), ISO 48-4 (Shore A) and ISO 868 (Shore D) standards.
The Calibration refers to:
• Dimensions of the Indentor and Annular foot
• Forces applied by the indentor and the annular foot
• Displacement of the indenter
• Duration of the test


Development and production 
The instrument is totally developed and produced in the plant of Gibitre Instruments in Italy.
All the mechanical parts are produced in the company workshop using modern CNC machines.
Components and sensors from well-known brands are selected in order to ensure the maximum reliability in the measures
Internal trained personnel takes care of all the production stages: assembly, start-up, calibration, packing, shipment and installation.



Type of Hardness units 
 
SHORE UNITS 
 
Shore A 
Standards: ISO 48-4, ASTM D2240, ISO 868

Application: Soft Rubber, Plastics, Elastomers

Sample standard thickness: 6 mm 
Shore A 
Indentor Force: 8.05 N (at 100 Shore)
Contact force: 1000 g
Indentation: 2.5 mm
Measurement Range: 0-100 Shore
Resolution: 0.01 Shore 
Shore D 
Standards: ISO 48-4, ASTM D2240, ISO 868

Application: Hard Rubber, Thermoplastics

Sample standard thickness: 6 mm 
Shore D 
Indentor Force: 44.5 N (at 100 Shore)
Contact force: 5000 g
Indentation: 2.5 mm
Measurement Range: 0-100 Shore
Resolution: 0.01 Shore 
Shore A0 
Standards: ISO 48-4

Application: Light Foams, Sponge Rubber, Gels, Human Tissue

Sample thickness: 6 mm 
Shore A0 
Indentor Force: 8.05 N (at 100 Shore)
Contact force: 1000 g
Indentation: 2.5 mm
Measurement Range: 0-100 Shore
Resolution: 0.01 Shore 
Shore 00 
Standards: ASTM D2240

Application: Light Foams, Sponge Rubber, Gels, Human Tissue

Sample thickness: 6 mm 
Shore 00 
Indentor Force: 1.111 N (at 100 Shore)
Contact force: 400 g
Indentation: 2.5 mm
Measurement Range: 0-100 Shore
Resolution: 0.01 Shore 
Shore AM 
Standards: ISO 48-4, ASTM D2240

Application: Small Technical Articles, O-rings

Sample thickness: 1.5-6 mm 
Shore AM 
Indentor Force: 0.76 N (at 100 Shore)
Contact force: 250 g
Indentation: 1.25 mm
Measurement Range: 0-100 Shore
Resolution: 0.01 Shore 
IRHD UNITS 
 
IRHD-M (MICRO) 
Standards: ISO 48-2, ASTM D1415

Application: Small Technical Articles, O-rings

Sample thickness: 1-5 mm 


IRHD-M (MICRO) 
Indentor Diameter: 0.395 mm
Pre-Load: 8.3 mN
Total Load: 153.3 mN
Anular Foot: 235 mN
Indentation: 0.3 mm
Measurement Range: 30-100 irhd
Resolution: 0.01 irhd 
IRHD-N (NORMAL) 
Standards: ISO 48-2, ASTM D1415

Application: Rubber Parts with Hardness >30 irhd

Sample thickness: 8-10 mm 
IRHD-N (NORMAL) 
Indentor Diameter: 2.5 mm
Pre-Load: 0.3 N
Total Load: 5.7 N
Anular Foot: 8.3 N
Indentation: 1.8 mm
Measurement Range: 30-85 irhd
Resolution: 0.01 irhd 
IRHD-H (HIGH HARDNESS) 
Standards: ISO 48-2, ASTM D1415

Application: Hard Rubber Parts with Hardness >85 irhd

Sample thickness: 8-10 mm 
IRHD-H (HIGH HARDNESS) 
Indentor Diameter: 1.0 mm
Pre-Load: 0.3 N
Total Load: 5.7 N
Anular Foot: 8.3 N
Indentation: 0.44 mm
Measurement Range: 85-100 irhd
Resolution: 0.01 irhd 
IRHD-L (LOW HARDNESS) 
Standards: ISO 48-2, ASTM D1415

Application: Soft Rubber Parts with Hardness <35 irhd

Sample thickness: 8-10 mm 
IRHD-L (LOW HARDNESS) 
Indentor Diameter: 5.0 mm
Pre-Load: 0.3 N
Total Load: 5.7 N
Anular Foot: 8.3 N
Indentation: 0.09-1.1 mm
Measurement Range: 10-35 irhd
Resolution: 0.01 irhd 
VLRH (VERY LOW RUBBER HARDNESS) 
Norme: ISO 48-3

Application: Soft Rubber Parts with Hardness <35 irhd

Sample thickness: 2 mm 
VLRH (VERY LOW RUBBER HARDNESS) 
Indentor Diameter: 2.5 mm
Pre-Load: 8.3 mN
Total Load: 100.0 mN
Anular Foot: 235 mN
Indentation: 1 mm
Measurement Range: < 35 irhd
Resolution: 0.01 VLRH 


Gibitre Instruments
Via dell'industria, 18
Bergamo (Italy)
te. +39 035 461146
www.gibitre.it
info@gibitre.it

Copyright Gibitre Instruments
Shore and IRHD Measuring Heads for Hardness Tester Automatic Hardness Check - Drive
Campi di applicazione  >  Prove su pneumatici  >  Rheocheck MD - Drive
Switchable
Hardness Measuring Heads
hardness testers units: Durómetro automático multicabezal: cabezal de medición intercambiable.
Get a Quotation

Shore and IRHD Measuring Heads for Hardness Tester Automatic Hardness Check - Drive

Applications

With the new generation of Drive Automatic Hardness Testers from Gibitre Instruments, tailor the instrument to your measurement needs. The interchangeable head system lets you swap Shore and IRHD heads on the motorized stand in seconds; the rigid quick coupling preserves perfect perpendicularity, a prerequisite for reliable results on your materials. This versatility suits labs that work across multiple measurement scales without multiplying tools: one hardness tester covers diverse needs, streamlining workflows and cutting setup time between tests.

All measuring heads comply with ISO 48-2, ISO 48-4, ASTM D2240, and ASTM D1415.

Why choose the Drive Automatic Hardness Check? It grows with you: additional heads can be added after purchase, expanding your lab’s measurement capabilities as new requirements emerge and safeguarding your investment. The Drive version’s configurability and rapid head change help you respond quickly to varying demands while maintaining continuity. In short, a
Sus necesidades de análisis

Your Testing Needs 

Do you need to test different products according to a specific hardness scale?
Do you need to evaluate incoming compounds and finished parts across multiple scales?
Do you require the flexibility to switch between various hardness scales without notice?

Whatever your needs, we offer the ideal setup to meet your requirements.

Versatility in One Instrument 

The Universal Support for Automatic Hardness Testers in the Drive version accommodates all available Shore, IRHD, and VLRH hardness units. Swapping measuring heads offers a versatile solution for research centers or labs that require measurements across various scales, as well as for companies that primarily use one scale but need occasional checks against others.

hardness testers units: Comprobación automática de la dureza - Accionamiento. Cabezal intercambiable aplicable al instrumento.
Comprobación automática de la dureza - Accionamiento. Cabezal intercambiable aplicable al instrumento.

Complete Hardness Testing for Simultaneous Use 

For companies conducting systematic production checks using different measurement scales (e.g., Shore A and Micro-IRHD), dedicated hardness units for each required scale are essential. The optimal setup, based on our experience, involves installing independent hardness testers connected to the same PC. This configuration allows multiple operators to use the instruments simultaneously without any interruptions.

hardness testers units: Comprobación automática de la dureza - Accionamiento. Cabezal intercambiable aplicable al instrumento.
Comprobación automática de la dureza - Accionamiento. Cabezal intercambiable aplicable al instrumento.
 
R & D: Interchangeable Hardness Units

Many instruments in one 

The solid quick coupling system allows the head to be replaced in seconds while ensuring its perfect pependicularity with respect to the support base.

To replace the measuring head:
- Remove the connecting cable
- Unscrew the locking screw
- Replace the head with the desired one
- Screw the locking screw
- Insert the connection cable

The instrument automatically recognizes the applied head and is immediately ready for testing.

hardness testers units: Comprobador automático de dureza - Durómetro de accionamiento con cabezales de medición Shore e IRHD intercambiables. Vista de un cabezal Shore con detalle del sistema de fijación. hardness testers units: Comprobador automático de dureza - Durómetro de accionamiento con cabezales de medición Shore e IRHD intercambiables. Vista de un cabezal Shore con detalle del sistema de fijación. hardness testers units: Comprobación automática de la dureza: sustitución del cabezal de medición.

Available Hardness Units 

Shore A,
Shore D,
Shore A0,
Shore 00,
Shore AM (micro),
IRHD-Micro,
IRHD-Normal,
IRHD-Hard,
IRHD-Low,
VLRH (Very Low Rubber Hardness).

hardness testers units: Durómetros automáticos multicabezal en versión Drive. Cabezal de medición intercambiable con caja de protección.
Durómetros automáticos multicabezal en versión Drive. Cabezal de medición intercambiable con caja de protección.

 

Control de producción: unidades autónomas

Complete hardness testers for simultaneous use 

For companies that need to perform systematic production checks against several different measurement scales (e.g., Shore A and Micro-IRHD), it is necessary for durometers to be available at the same time to perform measurements at the required scale.
The optimal solution we propose for such cases is the installation of multiple complete hardness testers connected to the same PC with a single software license. In this way the instruments can be used simultaneously and by several operators without any interruption.

Automatic performance of multiple tests on the sample 

International standards require the performance of multiple hardness tests on the specimen and the calculation of the median value.
The specimen holder plate with motorized rotation allows multiple tests to be performed automatically at different points on the specimen.
• The operator can set the number of tests to be performed automatically on the specimen and the angle of rotation between successive tests.

hardness testers units: Durómetros automáticos Hardness Check con cabezales Shore e irhd intercambiables. Esquema del instrumento que muestra el desplazamiento motorizado del cabezal y la rotación del plato para realizar ensayos automáticos en múltiples puntos de la probeta.
Durómetros automáticos Hardness Check con cabezales Shore e irhd intercambiables. Esquema del instrumento que muestra el desplazamiento motorizado del cabezal y la rotación del plato para realizar ensayos automáticos en múltiples puntos de la probeta.

Accredia Calibration of the hardness units 

Each Hardness Unit can be supplied with an ACCREDIA calibration certificate issued by the Accredia laboratory of Gibitre instruments.
The calibration is carried out according to the Technical Procedure approved by Accredia and in compliance with the requirements of the ISO 48-2 (IRHD), ISO 48-4 (Shore A) and ISO 868 (Shore D) standards.
The Calibration refers to:
• Dimensions of the Indentor and Annular foot
• Forces applied by the indentor and the annular foot
• Displacement of the indenter
• Duration of the test

hardness testers units: x hardness testers units: x hardness testers units: Servicio de calibración acreditado según la norma ISO 17025. Ejemplo de la primera página de un certificado de calibración emitido por el laboratorio de Gibitre Instruments que incluye los logotipos de Accredia e Ilac.
Producción

Development and production 

The instrument is totally developed and produced in the plant of Gibitre Instruments in Italy.
All the mechanical parts are produced in the company workshop using modern CNC machines.
Components and sensors from well-known brands are selected in order to ensure the maximum reliability in the measures
Internal trained personnel takes care of all the production stages: assembly, start-up, calibration, packing, shipment and installation.

hardness testers units: Orgullosamente fabricado en Italia
Orgullosamente fabricado en Italia

Technical specification

Type of Hardness units

SHORE UNITS

Shore A  Standards: ISO 48-4, ASTM D2240, ISO 868

Application: Soft Rubber, Plastics, Elastomers

Sample standard thickness: 6 mm 
Shore A  Indentor Force: 8.05 N (at 100 Shore)
Contact force: 1000 g
Indentation: 2.5 mm
Measurement Range: 0-100 Shore
Resolution: 0.01 Shore 
Shore D  Standards: ISO 48-4, ASTM D2240, ISO 868

Application: Hard Rubber, Thermoplastics

Sample standard thickness: 6 mm 
Shore D  Indentor Force: 44.5 N (at 100 Shore)
Contact force: 5000 g
Indentation: 2.5 mm
Measurement Range: 0-100 Shore
Resolution: 0.01 Shore 
Shore A0  Standards: ISO 48-4

Application: Light Foams, Sponge Rubber, Gels, Human Tissue

Sample thickness: 6 mm 
Shore A0  Indentor Force: 8.05 N (at 100 Shore)
Contact force: 1000 g
Indentation: 2.5 mm
Measurement Range: 0-100 Shore
Resolution: 0.01 Shore 
Shore 00  Standards: ASTM D2240

Application: Light Foams, Sponge Rubber, Gels, Human Tissue

Sample thickness: 6 mm 
Shore 00  Indentor Force: 1.111 N (at 100 Shore)
Contact force: 400 g
Indentation: 2.5 mm
Measurement Range: 0-100 Shore
Resolution: 0.01 Shore 
Shore AM  Standards: ISO 48-4, ASTM D2240

Application: Small Technical Articles, O-rings

Sample thickness: 1.5-6 mm 
Shore AM  Indentor Force: 0.76 N (at 100 Shore)
Contact force: 250 g
Indentation: 1.25 mm
Measurement Range: 0-100 Shore
Resolution: 0.01 Shore 

IRHD UNITS

IRHD-M (MICRO)  Standards: ISO 48-2, ASTM D1415

Application: Small Technical Articles, O-rings

Sample thickness: 1-5 mm 
IRHD-M (MICRO)  Indentor Diameter: 0.395 mm
Pre-Load: 8.3 mN
Total Load: 153.3 mN
Anular Foot: 235 mN
Indentation: 0.3 mm
Measurement Range: 30-100 irhd
Resolution: 0.01 irhd 
IRHD-N (NORMAL)  Standards: ISO 48-2, ASTM D1415

Application: Rubber Parts with Hardness >30 irhd

Sample thickness: 8-10 mm 
IRHD-N (NORMAL)  Indentor Diameter: 2.5 mm
Pre-Load: 0.3 N
Total Load: 5.7 N
Anular Foot: 8.3 N
Indentation: 1.8 mm
Measurement Range: 30-85 irhd
Resolution: 0.01 irhd 
IRHD-H (HIGH HARDNESS)  Standards: ISO 48-2, ASTM D1415

Application: Hard Rubber Parts with Hardness >85 irhd

Sample thickness: 8-10 mm 
IRHD-H (HIGH HARDNESS)  Indentor Diameter: 1.0 mm
Pre-Load: 0.3 N
Total Load: 5.7 N
Anular Foot: 8.3 N
Indentation: 0.44 mm
Measurement Range: 85-100 irhd
Resolution: 0.01 irhd 
IRHD-L (LOW HARDNESS)  Standards: ISO 48-2, ASTM D1415

Application: Soft Rubber Parts with Hardness <35 irhd

Sample thickness: 8-10 mm 
IRHD-L (LOW HARDNESS)  Indentor Diameter: 5.0 mm
Pre-Load: 0.3 N
Total Load: 5.7 N
Anular Foot: 8.3 N
Indentation: 0.09-1.1 mm
Measurement Range: 10-35 irhd
Resolution: 0.01 irhd 
VLRH (VERY LOW RUBBER HARDNESS)  Norme: ISO 48-3

Application: Soft Rubber Parts with Hardness <35 irhd

Sample thickness: 2 mm 
VLRH (VERY LOW RUBBER HARDNESS)  Indentor Diameter: 2.5 mm
Pre-Load: 8.3 mN
Total Load: 100.0 mN
Anular Foot: 235 mN
Indentation: 1 mm
Measurement Range: < 35 irhd
Resolution: 0.01 VLRH 
References
Gibitre Automatic Hardness Check
is currently installed in
44 countries
Request the List of top References
Download
Brief product leaflet
General catalogue mail request

Calibration certificate
example
CE certificate
example
Automatic Hardness Check - Drive
Vedi anche: Comprobación automática de la dureza - Accionamiento. Vista completa del instrumento con cabezal IRHD.
See Also   >
News
Call to action
Ask for quotation
a guided way to ask
for a quotation
Mail
info@gibitre.it
The good old e-mail
ready for every season
Phone
+39 035 460146
We welcome your calls Monday through Friday from 8:30 a.m. to 5:30 p.m. in your local time zone.
Newsletter
Subscribe
Stay updated
with the last news
of your sector
Local agent
from: -
See the whole list

In your country
in your language
at your service
Gibitre Instruments S.r.l., Via dell'industria 73, 24126 Bergamo Italia, pec@gibitre-instruments.it P. IVA: IT02827900164 CCIAA REA Bergamo: 326486 | ©2018 - 2026 Gibitre Instruments
Optimist.it
Welcome to the Gibitre Instruments web site
Please chose the preferred Cookie Management.
Benvenuti nel sito Gibitre Instruments
Per continuare scegliete la Gestione dei Cookie che preferite.
Cookies policy
For detailed informations about the use of cookies, please read our
Cookies Management Practice.

Gestione dei Cookies
Per maggiori informazioni sui cookie utilizzati consultate la nostra
Procedura sull'Uso dei Cookies.