ISO 17025 Accredited Calibration
Gibitre Instruments is Accredited ACCREDIA Calibration Laboratory according to ISO 17025:2018 standard and provides calibration service for Hardness (Shore & IRHD) and Tensile (Force, Elongation, Speed) Testers



Accredia Calibration Services 
Gibitre Instruments' metrology laboratory has been accredited as an Accredia Calibration Laboratory (LAT 00455) since 2005.
The calibration center complies with the ISO 17025:2018 standard.
The center is currently accredited for the calibration of:
- IRHD (Micro, Normal, Hard, Low) hardness testers according to ISO 48-9
- Shore hardness testers (A and D) according to ISO 48-9 and ISO 868
- Dynamometers - Force according to ISO 7500-1
- Dynamometers - Elongation according to ISO 9513 and ISO 5893
- Dynamometers - Speed according to ISO 5893 and ASTM E2658.


Official Calibration of Shore and IRHD Hardness Testers 
The metrological laboratory of Gibitre Instruments has developed technical procedures and fastening devices for ACCREDIA calibration of IRHD and Shore durometers produced by all the major world producers.

Calibrations are performed in the metrology room of Gibitre Instruments, with controlled environmental conditions.

The Calibration of Hasrdness testers produced by Gibitre can be performed at customer site.


Official Calibration of Tensile testers 
Accredia calibration of:
• Force applied in Traction and Compression up to 20 kN
• Deformation (Strain gauges) between 10 and 1000 mm
• Crosshead displacement between 0 and 1500 mm
• Crosshead displacement speed between 0.1 and 1000 mm/min.

Calibration can be carried out at Gibitre headquarters and at the customer's laboratory.




Why an instrument should be calibrated ? 
The calibrations allow you to determine the error of indication of instruments in order to ensure more precise and reliable measurement results.
The calibrations are carried out by comparing the indication of the instrument with the measurement of corresponding known values ​​with the relative uncertainties.
The calibration process of instruments and samples by laboratories accredited according to ISO / IEC 17025 consists in the comparison with a higher level reference sample and thus allows the measurements they produce to acquire the metrological traceability to national or international samples.
Calibration is necessary for the compliance of a measuring equipment with the requirements for their use.
Normally, equipment calibration is performed:
• Before they are put into service;
• When adjustments or repairs are made;
• If foreseen by the contract with the client, before and after the setting up.
The outcome of the calibration is reported on the calibration certificate issued at the end of the activity.
The accreditation of the laboratories that perform the calibrations ensures the metrological traceability of national or international samples over time.
The ultimate goal is to reduce the margins of error for achieving more precise and reliable measurements.


Which is the meaning of the iso 17025 accreditation of a laboratory? 
Accreditation ensures that the calibration laboratory has all the requirements required by the standards for carrying out conformity assessment activities.
Accreditation is the certification, by an entity acting as super partes guarantor, of the calibration laboratory's competence, independence and impartiality.
The accreditation of the laboratory confers on the calibration certificates issued on the market, a high degree of reliability in terms of quality and safety of the instruments subjected to verification, and guarantees their recognition on international markets.
Worldwide, accreditation is carried out on the basis of the international standard ISO / IEC 17011. Within the European Union, the European Regulation 765/2008 provides that each member state appoints its own unique national accreditation body and has conferred for the first time to this activity a legal status, recognizing it as an expression of public authority.
In Italy, the single accreditation body designated by the government is Accredia.
Accredia is a member of the international networks of the accreditation bodies and is the signatory of the relevant international mutual recognition agreements, thanks to the passing of a peer evaluation process.

A Quick and Safe service. 
Gibitre has a solid experience regarding the manipulation and calibration of hardness testers and has performed more that 1500 calibration since 2005.
The measurements made with the instrument before any adjustment and calibration operations and any variations with the pre-calibration conditions are recorded.
By pre-arranging the delivery date of the instruments with the Gibitre sales office, we can perform the back-shipment of the instrument within 24 hours from delivery.
Instruments that do not meet the Accredia calibration requirements are returned without charging calibration service.




How we calibrate your Hardness Tester ? 
Accredia calibration for each type of durometer is carried out according to the relevant Technical Procedure approved by ACCREDIA and which includes all the measures required by the reference standards.
The calibration involves the following steps:
• Minimum thermal conditioning of 4 hours at controlled temperature and humidity.
• Functional verification and verification of the pre-calibration reading of the instrument with comparison samples.
• Possible adjustment of the instrument
• Dimensional Calibration of the Indentor and of the Anular Foot
• Calibration of Forces applied by the Indentor and by the Anular Foot
• Calibration of the Displacement of the Indentor
• Calibration of the time of duration of the test
• Verification of the post-calibration reading of the instrument with comparison samples.
• Preparation of the Accredia Calibration Certificate which shows all the measures described above.
At the end, the instrument is packed for the shipment.


How we calibrate your Tensile tester ? 
Accredia calibrations of force and displacement measurements are carried out according to Technical Procedures approved by ACCREDIA.

Calibration activities are preceded by measurement of the laboratory temperature (which must be within the limits required by the standards and specified in the Accreditation Table) and verification that the instrument is functioning properly.

Next:
- Force measurements are made by comparing the load cell measurements of the instrument being calibrated with those obtained with the reference instrument. The comparison is repeated 3 times for each expected measurement scale
- Measurements for strain gauge differential elongation, crosshead displacement, velocity and reference length (initial strain gauge distance) are made by comparing the reading of the instrumentin calibration with those obtained with the Optical Line and reference chronometer.

Upon completion, calibration certificates are issued that include all measurements taken, calculation of the uncertainty of the measurements, and analysis of the conformity of the results with the respective reference standards.

What happens if the instrument does not measure correctly ? 
• If, during calibration, all the characteristics of the instrument are found to be in conformity with respect to what is required by the reference standard, the Declaration of Conformity of the instrument is recorded in the Calibration Certificate, certifying its full conformity for use.

• In the case of calibrations performed at Gibitre's facility, and the instrument does not function properly or cannot be adjusted to achieve full compliance with the requirements of the reference standard, the calibration is discontinued and the instrument is returned without charge.

• In the case of calibrations carried out at the customer's site, if the instrument does not function properly or if the environmental conditions are not within the limits prescribed by the reference standards, the calibration is discontinued and the customer is charged only for the costs related to the technician's travel.



Place of performance of the Calibrations 
Gibitre Instruments is accredited for calibrations:
- At the Gibitre metrology laboratory
- At the customer's laboratory. 
 
 
Calibration of Hardness Testers 
 
IRHD (Micro, Normal, Hard, Low) hardness testers  
According to ISO 48-9 & ISO 48-2 Standards 
Shore hardness testers A and D 
According to ISO 48-9, ISO 48-4 and ISO 868 Standards 
 
 
Calibration of Tensile Testers (UTM) 
 
Calibration of Force 
According to ISO 7500-1.
 
Calibration of Elongation 
According to ISO 9513 and ISO 5893 
Calibration of Speed 
According to ISO 5893 and ASTM E2658 
Note about Calibration at customer site 
Calibration of Shore & IRHD Hardness Testers performed at the customer's site does not include dimensional calibration of the indenter and can only be performed for Gibitre brand instruments 


Gibitre Instruments
Via dell'industria, 18
Bergamo (Italy)
te. +39 035 461146
www.gibitre.it
info@gibitre.it

Copyright Gibitre Instruments
Gibitre Instruments is Accredited ACCREDIA Calibration Laboratory according to ISO 17025:2018 standard and provides calibration service for Hardness (Shore & IRHD) and Tensile (Force, Elongation, Speed) Testers
Campi di applicazione  >  Prove su pneumatici  >  Rheocheck MD - Drive
ISO 17025
Accredited Calibration
iso 17025 calibrations: x
Get a Quotation


ISO 17025 Accredited Calibration - 지비트르 인스트루먼트는 ISO 17025:2018 표준에 따른 공식 ACCREDIA 교정 실험실 00455호이며 경도(쇼어 및 IRHD) 및 인장(힘, 연신율, 속도) 시험기에 대한 교정 서비스를 제공합니다.
Gibitre Instruments의 측정학 실험실은 2005년부터 공인된 교정 실험실 (LAT 00455)입니다.
이 교정 실험실은 ISO 17025:2018 표준을 준수합니다.
현재 해당 실험실은 다음과 같은 교정에 대해 인증을 받았습니다:
경도 측정기
• ISO 48-9에 따른 IRHD (미세, 일반, 경도, 저경도)
• ISO 48-9 및 ISO 868에 따른 쇼어 경도 시험기 A 및 D
인장 시험기
• ISO 7500-1에 따른 힘
• ISO 9513 및 ISO 5893에 따른 신장 및 변위
• ISO 5893 및 ASTM E2658에 따른 속도

Gibitre Instruments is Accredited ACCREDIA Calibration Laboratory according to ISO 17025:2018 standard and provides calibration service for Hardness (Shore & IRHD) and Tensile (Force, Elongation, Speed) Testers

Accredia Calibration Services 

Gibitre Instruments' metrology laboratory has been accredited as an Accredia Calibration Laboratory (LAT 00455) since 2005.
The calibration center complies with the ISO 17025:2018 standard.
The center is currently accredited for the calibration of:
- IRHD (Micro, Normal, Hard, Low) hardness testers according to ISO 48-9
- Shore hardness testers (A and D) according to ISO 48-9 and ISO 868
- Dynamometers - Force according to ISO 7500-1
- Dynamometers - Elongation according to ISO 9513 and ISO 5893
- Dynamometers - Speed according to ISO 5893 and ASTM E2658.

Download the Accreditation Certificate
iso 17025 calibrations: 에어컨이 설치된 지비트르 교정 실험실
에어컨이 설치된 지비트르 교정 실험실

Official Calibration of Shore and IRHD Hardness Testers 

The metrological laboratory of Gibitre Instruments has developed technical procedures and fastening devices for ACCREDIA calibration of IRHD and Shore durometers produced by all the major world producers.

Calibrations are performed in the metrology room of Gibitre Instruments, with controlled environmental conditions.

The Calibration of Hasrdness testers produced by Gibitre can be performed at customer site.

Download the Accreditation Table
iso 17025 calibrations: 지비트레 경도계. ISO 17025 인증 교정 서비스. ISO 48-4 표준에 따른 쇼어 경도계 교정. iso 17025 calibrations: 지비트레 경도계. ISO 17025 인증 교정 서비스. ISO 48-4 표준에 따른 쇼어 경도계 교정. iso 17025 calibrations: 지비트르 교정 서비스. 쇼어 경도 시험기 교정. 힘 확인을 위한 디지털 디스플레이가 있는 로드셀. iso 17025 calibrations: ISO 17025 인증: 베어리스 브랜드 기기의 캘리브레이션 예시. iso 17025 calibrations: ISO 17025에 따른 공인 교정 서비스: 베어리스 HPE 경도 시험기의 교정 예시.

Official Calibration of Tensile testers 

Accredia calibration of:
Force applied in Traction and Compression up to 20 kN
• Deformation (Strain gauges) between 10 and 1000 mm
• Crosshead displacement between 0 and 1500 mm
• Crosshead displacement speed between 0.1 and 1000 mm/min.


Calibration can be carried out at Gibitre headquarters and at the customer's laboratory.

Download the Accreditation Table
iso 17025 calibrations: 텐서-체크 동력계. ISO 17025 인증 교정 서비스. ISO 7500-1 표준에 따른 하중 셀 교정. iso 17025 calibrations: 텐서-체크 동력계. ISO 17025 인증 교정 서비스. ISO 7500-1 표준에 따른 하중 셀 교정. iso 17025 calibrations: 계측기 캘리브레이션 서비스. 텐서 체크 동력계에 로드셀을 부착하기 위한 시스템 세부 정보입니다. iso 17025 calibrations: ISO 17025에 따른 Accredia 캘리브레이션 서비스. 동력계 교정. 차동 연신율 보정. iso 17025 calibrations: ISO 17025 공인 캘리브레이션 서비스. 동력계 캘리브레이션. 속도 보정. iso 17025 calibrations: 공인 교정 서비스 설명 - 1부 iso 17025 calibrations: 공인 교정 서비스에 대한 설명 - 2부 iso 17025 calibrations: 공인 교정 서비스에 대한 설명 - 파트 3
 

Why an instrument should be calibrated ? 

The calibrations allow you to determine the error of indication of instruments in order to ensure more precise and reliable measurement results.
The calibrations are carried out by comparing the indication of the instrument with the measurement of corresponding known values ​​with the relative uncertainties.
The calibration process of instruments and samples by laboratories accredited according to ISO / IEC 17025 consists in the comparison with a higher level reference sample and thus allows the measurements they produce to acquire the metrological traceability to national or international samples.
Calibration is necessary for the compliance of a measuring equipment with the requirements for their use.
Normally, equipment calibration is performed:
• Before they are put into service;
• When adjustments or repairs are made;
• If foreseen by the contract with the client, before and after the setting up.
The outcome of the calibration is reported on the calibration certificate issued at the end of the activity.
The accreditation of the laboratories that perform the calibrations ensures the metrological traceability of national or international samples over time.
The ultimate goal is to reduce the margins of error for achieving more precise and reliable measurements.

More info in Accredia web site
iso 17025 calibrations: ISO 17025 인증 교정 서비스. Gibitre Instruments 실험실에서 발행한 교정 인증서의 첫 페이지 예시. Accredia 및 ILAC 로고가 포함되어 있습니다.
ISO 17025 인증 교정 서비스. Gibitre Instruments 실험실에서 발행한 교정 인증서의 첫 페이지 예시. Accredia 및 ILAC 로고가 포함되어 있습니다.

Which is the meaning of the iso 17025 accreditation of a laboratory? 

Accreditation ensures that the calibration laboratory has all the requirements required by the standards for carrying out conformity assessment activities.
Accreditation is the certification, by an entity acting as super partes guarantor, of the calibration laboratory's competence, independence and impartiality.
The accreditation of the laboratory confers on the calibration certificates issued on the market, a high degree of reliability in terms of quality and safety of the instruments subjected to verification, and guarantees their recognition on international markets.
Worldwide, accreditation is carried out on the basis of the international standard ISO / IEC 17011. Within the European Union, the European Regulation 765/2008 provides that each member state appoints its own unique national accreditation body and has conferred for the first time to this activity a legal status, recognizing it as an expression of public authority.
In Italy, the single accreditation body designated by the government is Accredia.
Accredia is a member of the international networks of the accreditation bodies and is the signatory of the relevant international mutual recognition agreements, thanks to the passing of a peer evaluation process.

More info about Accreditation
Advantages of Accredited services

A Quick and Safe service. 

Gibitre has a solid experience regarding the manipulation and calibration of hardness testers and has performed more that 1500 calibration since 2005.
The measurements made with the instrument before any adjustment and calibration operations and any variations with the pre-calibration conditions are recorded.
By pre-arranging the delivery date of the instruments with the Gibitre sales office, we can perform the back-shipment of the instrument within 24 hours from delivery.
Instruments that do not meet the Accredia calibration requirements are returned without charging calibration service.

iso 17025 calibrations: 기술 지원 서비스. Gibitre는 기술 지원 시간 최소화에 큰 주의를 기울입니다. 시계가 있는 이미지.
기술 지원 서비스. Gibitre는 기술 지원 시간 최소화에 큰 주의를 기울입니다. 시계가 있는 이미지.
iso 17025 calibrations: 정비 및 교정 서비스. 기술자에게 제공되는 교정 도구 세트.
Safe.... and Risk-Free

How we calibrate your Hardness Tester ? 

Accredia calibration for each type of durometer is carried out according to the relevant Technical Procedure approved by ACCREDIA and which includes all the measures required by the reference standards.
The calibration involves the following steps:
• Minimum thermal conditioning of 4 hours at controlled temperature and humidity.
• Functional verification and verification of the pre-calibration reading of the instrument with comparison samples.
• Possible adjustment of the instrument
• Dimensional Calibration of the Indentor and of the Anular Foot
• Calibration of Forces applied by the Indentor and by the Anular Foot
• Calibration of the Displacement of the Indentor
• Calibration of the time of duration of the test

Verification of the post-calibration reading of the instrument with comparison samples.
• Preparation of the Accredia Calibration Certificate which shows all the measures described above.
At the end, the instrument is packed for the shipment.

iso 17025 calibrations: 쇼어 A 경도 시험기. 경도계의 압자 및 환형 발에 대한 참조 측정값이 포함된 기술 도면입니다. iso 17025 calibrations: 쇼어 A 경도 시험기. 경도계의 압자 및 환형 발에 대한 참조 측정값이 포함된 기술 도면입니다. iso 17025 calibrations: 쇼어 A 경도 시험기. 경도계의 압자 및 환형 발에 대한 참조 측정값이 포함된 기술 도면입니다.

How we calibrate your Tensile tester ? 

Accredia calibrations of force and displacement measurements are carried out according to Technical Procedures approved by ACCREDIA.

Calibration activities are preceded by measurement of the laboratory temperature (which must be within the limits required by the standards and specified in the Accreditation Table) and verification that the instrument is functioning properly.

Next:
- Force measurements are made by comparing the load cell measurements of the instrument being calibrated with those obtained with the reference instrument. The comparison is repeated 3 times for each expected measurement scale
- Measurements for strain gauge differential elongation, crosshead displacement, velocity and reference length (initial strain gauge distance) are made by comparing the reading of the instrumentin calibration with those obtained with the Optical Line and reference chronometer.

Upon completion, calibration certificates are issued that include all measurements taken, calculation of the uncertainty of the measurements, and analysis of the conformity of the results with the respective reference standards.

What happens if the instrument does not measure correctly ? 

• If, during calibration, all the characteristics of the instrument are found to be in conformity with respect to what is required by the reference standard, the Declaration of Conformity of the instrument is recorded in the Calibration Certificate, certifying its full conformity for use.

• In the case of calibrations performed at Gibitre's facility, and the instrument does not function properly or cannot be adjusted to achieve full compliance with the requirements of the reference standard, the calibration is discontinued and the instrument is returned without charge.

• In the case of calibrations carried out at the customer's site, if the instrument does not function properly or if the environmental conditions are not within the limits prescribed by the reference standards, the calibration is discontinued and the customer is charged only for the costs related to the technician's travel.

iso 17025 calibrations: Gibitre의 애프터서비스. 엄지손가락을 치켜든 상업적 이미지.
Gibitre의 애프터서비스. 엄지손가락을 치켜든 상업적 이미지.

Technical specification

Place of performance of the Calibrations  Gibitre Instruments is accredited for calibrations:
- At the Gibitre metrology laboratory
- At the customer's laboratory. 

Calibration of Hardness Testers

IRHD (Micro, Normal, Hard, Low) hardness testers   According to ISO 48-9 & ISO 48-2 Standards  Shore hardness testers A and D  According to ISO 48-9, ISO 48-4 and ISO 868 Standards 

Calibration of Tensile Testers (UTM)

Calibration of Force  According to ISO 7500-1.
 
Calibration of Elongation  According to ISO 9513 and ISO 5893  Calibration of Speed  According to ISO 5893 and ASTM E2658  Note about Calibration at customer site  Calibration of Shore & IRHD Hardness Testers performed at the customer's site does not include dimensional calibration of the indenter and can only be performed for Gibitre brand instruments 
Download
Brief product leaflet
General catalogue mail request

Calibration certificate
example
Tensor Check Profile - PC
Vedi anche: 텐서-체크 동력계. 계기 전체 보기.
See Also   >
Automatic Hardness Check - Drive
Vedi anche: 자동 경도 검사 - 드라이브. IRHD 헤드가 있는 기기의 전체 보기.
See Also   >
Manual Digital Hardness Check - Drive
Vedi anche: 수동 경도 검사 드라이브 버전의 경도 시험기. 스탠드에 장착된 기기 보기.
See Also   >
News
Call to action
Ask for quotation
a guided way to ask
for a quotation
Mail
info@gibitre.it
The good old e-mail
ready for every season
Phone
+39 035 460146
We welcome your calls Monday through Friday from 8:30 a.m. to 5:30 p.m. in your local time zone.
Newsletter
Subscribe
Stay updated
with the last news
of your sector
Local agent
from: -
See the whole list

In your country
in your language
at your service
Gibitre Instruments S.r.l., Via dell'industria 73, 24126 Bergamo Italia, pec@gibitre-instruments.it P. IVA: IT02827900164 CCIAA REA Bergamo: 326486 | ©2018 - 2026 Gibitre Instruments
Optimist.it
Welcome to the Gibitre Instruments web site
Please chose the preferred Cookie Management.
Benvenuti nel sito Gibitre Instruments
Per continuare scegliete la Gestione dei Cookie che preferite.
Cookies policy
For detailed informations about the use of cookies, please read our
Cookies Management Practice.

Gestione dei Cookies
Per maggiori informazioni sui cookie utilizzati consultate la nostra
Procedura sull'Uso dei Cookies.