Tensile tester combined with Electrical Resistivity tester
Measure of Electrical Resistivity under dynamic conditions



 
This integrated setup pairs an Electronic Dynamometer with a Digital Multimeter, enabling a single station to investigate how conductive and semiconductive products respond throughout deformation cycles. Dedicated specimen-holder clamps apply tension, compression, or bending while capturing real-time resistance measurement as load is applied—a direct method to correlate strain with electrical response in materials. The multimeter spans 10 micro-ohms to 120 mega-ohms, accommodating samples with very low to very high resistances. Tests run at ambient conditions or in a climate chamber from -40 °C to +250 °C to assess thermal effects on mechanical and electrical behavior. Delivered as ready-to-use testing tools, the system streamlines setup and ensures repeatable results.

Overview 
The combination of Electronic Dynamometer and Digital Multimeter permits to measure how the behavior of conductive and semiconductive products changes when subjected to deformation cycles.

It is possible to subject the specimens to deformation in traction, compression or bending.

The measurements can be made at room temperature or in a climatic chamber (between -40 °C and +250 °C).

The multimeter allows you to measure electrical resistance between 10 Micro-Ohms and 120 Mega-Ohms.


Instrument Setup 
Instrument configuration includes:
- Gibitre standard Tensile Tester
- High-Accuracy-Digital Multimeter
- Electrically insulated clamps to allow the measurement of the electrical resistance of the specimen during the applied deformation cycle.

The instrument can be equipped with a climatic chamber for carrying out tests at a controlled temperature.

The TensorCheck Software allows the complete and simultaneous control of the instrument, the multimeter and the Environmental Chamber and processes the Force, Displacement, Temperature and Resistivity signals.




Environmental chamber 
Test Chamber for the performance of tests with controlled temperature (between -40°C and +250°C).
The environmental chamber can be manually displaced from the test area to the back of the instrument for testing with or without temperature control.
Differential extensometer to be installed inside the chamber is available.


Example: Resistivity in Flexion 
Test conditions:
- Test in Flexion
- Applied cyclic deformation: 2 mm
- Deformation speed 10 mm / min
- Graphic representation: Ohm vs Seconds
- Frequency of saving curve points: 20 Hz.
- Temperature: room temperature


Example: Resistivity in Traction at +125°C 
Test conditions:
- Traction test
- Applied cyclic deformation: 100 mm
- Deformation speed 100 mm / min
- Graphic representation: Ohm vs % Strain
- Frequency of saving curve points: 20 Hz.
- Temperature: +125 °C




Example: Resistivity in Compression at -40°C 
Test conditions:
- Compression test
- Sample: Ø 29 mm, h 12.5 mm
- Applied cyclic deformation: 10 mm
- Deformation speed 20 mm/min
- Graphic representation: Ohm vs % Strain
- Frequency of saving curve points: 20 Hz.
- Temperature: -40 °C


Test Cycle 
The TensorCheck software allows you to prepare test cycles that include the sequence of operations that the instrument must perform to apply the dynamic cycle intended for the test.
The test cycle includes operations of:
- force adjustment
- displacement adjustment
- temperature regulation (with climatic chamber installed)
- zeroing operations
- control of the production of the curves

Recursive loops can be defined for performing cyclic operations


Test Curves 
• The curves relating to the tests carried out are shown in different colors to associate them immediately with the relative results.
• By selecting a result, the corresponding curve is automatically highlighted.
• The graphical functions integrated in the programs (scale settings, the number of divisions and zoom) allow you to analyze the curves in detail.
• All the curves are saved in the database together with the test results.




Numerical Results produced 
The TensorCheck software allows you to define for each test method which results you want to calculate.
The specific results related to resistivity measurements are:
- Resistivity at set Force
- Resistivity at set Stress
- Resistivity to set Deformation


Management of Test Results 
The results and test curves of all the tests carried out are saved in the Gibitre SQL database and are available through the Datagest program.

Datagest is the Laboratory Information Management System (LIMS) which is always installed in combination with all Gibitre instrument-control programs.
The program is the collector for all the test result produced with the instruments connected and permits to manage the common Archives used by the instruments (Product List, Customer List, Tolerance limits, Order List, etc)


Export of test Curves 
It is possible to export the points of the test curves in a .csv file
For each test point, the file reports: Force, Effort, Deformation, Traverse Displacement, Time from Start, Electrical Resistance, Temperature.



Resistance measurement range 
10 Micro-Ohm to 120 Mega-Ohm 


Gibitre Instruments
Via dell'industria, 18
Bergamo (Italy)
te. +39 035 461146
www.gibitre.it
info@gibitre.it

Copyright Gibitre Instruments
Measure of Electrical Resistivity under dynamic conditions
Campi di applicazione  >  Prove su pneumatici  >  Rheocheck MD - Drive
Tensile tester combined with Electrical Resistivity tester
tensor tester resistivity option: Tensor-Check Dynamometer: Gerätekonfiguration mit Multimeter für Widerstandsmessungen.
Get a Quotation

Measure of Electrical Resistivity under dynamic conditions

Applications

This integrated setup pairs an Electronic Dynamometer with a Digital Multimeter, enabling a single station to investigate how conductive and semiconductive products respond throughout deformation cycles. Dedicated specimen-holder clamps apply tension, compression, or bending while capturing real-time resistance measurement as load is applied—a direct method to correlate strain with electrical response in materials. The multimeter spans 10 micro-ohms to 120 mega-ohms, accommodating samples with very low to very high resistances. Tests run at ambient conditions or in a climate chamber from -40 °C to +250 °C to assess thermal effects on mechanical and electrical behavior. Delivered as ready-to-use testing tools, the system streamlines setup and ensures repeatable results.
Resistivity under dynamic conditions

Overview 

The combination of Electronic Dynamometer and Digital Multimeter permits to measure how the behavior of conductive and semiconductive products changes when subjected to deformation cycles.

It is possible to subject the specimens to deformation in traction, compression or bending.

The measurements can be made at room temperature or in a climatic chamber (between -40 °C and +250 °C).

The multimeter allows you to measure electrical resistance between 10 Micro-Ohms and 120 Mega-Ohms.

tensor tester resistivity option: Dynamometer mit Option für Widerstandsmessungen. Biegeversuch mit isolierten Klemmen und leitfähigem Prüfkörper. tensor tester resistivity option: Dynamometer mit Option für Widerstandsmessungen. Biegeversuch mit isolierten Klemmen und leitfähigem Prüfkörper. tensor tester resistivity option: Tensor-Check Dynamometer mit optionalem Multimeter: Detailaufnahme des Biegetests. tensor tester resistivity option: Tensor-Check Dynamometer mit optionalem Multimeter: Biegetest Detail. tensor tester resistivity option: Tensor-Check mit Digitalmultimeter: Kurvenbeispiel und zyklische Testergebnisse.

Instrument Setup 

Instrument configuration includes:
- Gibitre standard Tensile Tester
- High-Accuracy-Digital Multimeter
- Electrically insulated clamps to allow the measurement of the electrical resistance of the specimen during the applied deformation cycle.

The instrument can be equipped with a climatic chamber for carrying out tests at a controlled temperature.

The TensorCheck Software allows the complete and simultaneous control of the instrument, the multimeter and the Environmental Chamber and processes the Force, Displacement, Temperature and Resistivity signals.

tensor tester resistivity option: Tensor-Check-Dynamometer mit Multimeter zur Messung des dynamischen Widerstands. Detailansicht des Displays des an das Gerät angeschlossenen Keythley-Multimeters. tensor tester resistivity option: Tensor-Check-Dynamometer mit Multimeter zur Messung des dynamischen Widerstands. Detailansicht des Displays des an das Gerät angeschlossenen Keythley-Multimeters. tensor tester resistivity option: Dynamometer Tensor-Check. Gesamtansicht des Geräts. tensor tester resistivity option: Gibitre-Software. Programm zur Verwendung des Kraftmessers Tensor Check. Hauptseite der Software. tensor tester resistivity option: Tensor-Check Dynamometer: Gerätekonfiguration mit Multimeter für Widerstandsmessungen. tensor tester resistivity option: Tensor-Check Dynamometer mit optionalem Multimeter: Kompressionsprüfung im Detail. tensor tester resistivity option: Tensor-Check Dynamometer mit optionalem Multimeter: Detailaufnahme des Biegetests. tensor tester resistivity option: Tensor-Check Dynamometer mit optionalem Multimeter: Zugversuch Detail.

Environmental chamber 

Test Chamber for the performance of tests with controlled temperature (between -40°C and +250°C).
The environmental chamber can be manually displaced from the test area to the back of the instrument for testing with or without temperature control.
Differential extensometer to be installed inside the chamber is available.

tensor tester resistivity option: Tensor-Check-Dynamometer mit Wärmekammer. Gesamtansicht des Geräts. tensor tester resistivity option: Tensor-Check-Dynamometer mit Wärmekammer. Gesamtansicht des Geräts. tensor tester resistivity option: Tensor-Check-Dynamometer mit Klimakammer. Vorderansicht des Geräts mit geöffneter Klimakammer. tensor tester resistivity option: die Klimakammer für den Leistungsprüfstand kann für Hoch- oder Tieftemperaturtests verwendet werden
 
Examples of Test Cycles

Example: Resistivity in Flexion 

Test conditions:
- Test in Flexion
- Applied cyclic deformation: 2 mm
- Deformation speed 10 mm / min
- Graphic representation: Ohm vs Seconds
- Frequency of saving curve points: 20 Hz.
- Temperature: room temperature

tensor tester resistivity option: Dynamometer mit Option für Widerstandsmessungen. Biegeversuch mit isolierten Klemmen und leitfähigem Prüfkörper. tensor tester resistivity option: Dynamometer mit Option für Widerstandsmessungen. Biegeversuch mit isolierten Klemmen und leitfähigem Prüfkörper. tensor tester resistivity option: Tensor-Check Dynamometer mit optionalem Multimeter: Detailaufnahme des Biegetests. tensor tester resistivity option: Tensor-Check Dynamometer mit Digitalmultimeter. Beispiel eines Prüfberichts mit Kraft-Widerstands-Kurven für einen zyklischen Belastungstest. tensor tester resistivity option: tensor-Check-resistivity-option: Beispiel für eine zyklische Testkurve. tensor tester resistivity option: Tensor-Check mit Digitalmultimeter: Kurvenbeispiel und zyklische Testergebnisse. tensor tester resistivity option: Tensor Check mit angeschlossenem Multimeter. Beispiel für einen Biegetestzyklus.

Example: Resistivity in Traction at +125°C 

Test conditions:
- Traction test
- Applied cyclic deformation: 100 mm
- Deformation speed 100 mm / min
- Graphic representation: Ohm vs % Strain
- Frequency of saving curve points: 20 Hz.
- Temperature: +125 °C

tensor tester resistivity option: Kraftmessgerät mit in die Software integriertem Multimeter. Zugprüfung mit isolierten Klemmen und leitfähigem Prüfling. tensor tester resistivity option: Kraftmessgerät mit in die Software integriertem Multimeter. Zugprüfung mit isolierten Klemmen und leitfähigem Prüfling. tensor tester resistivity option: Tensor-Check Dynamometer mit optionalem Multimeter: Zugversuch Detail. tensor tester resistivity option: Gibitre Dynamometer mit Digitalmultimeter: Beispiel für einen Bericht über die Messung von Widerstand und Dehnung in einem zyklischen Test. tensor tester resistivity option: TensorCheck mit Multimeter. Widerstand vs. Dehnung Testbericht für verschiedene Materialien. tensor tester resistivity option: Farbige Testkurven: die Ergebnisse auf einen Blick tensor tester resistivity option: Tensor-Check-Dynamometer mit integriertem Digitalmultimeter zur dynamischen Messung des Widerstands leitfähiger Produkte. Beispiel für die Einstellung eines Zugprüfzyklus. tensor tester resistivity option: Tensor-Check-Dynamometer mit Konfiguration für die dynamische Messung des elektrischen Widerstands leitfähiger Produkte. Beispiel für einen Testzyklus für Zugversuche.

Example: Resistivity in Compression at -40°C 

Test conditions:
- Compression test
- Sample: Ø 29 mm, h 12.5 mm
- Applied cyclic deformation: 10 mm
- Deformation speed 20 mm/min
- Graphic representation: Ohm vs % Strain
- Frequency of saving curve points: 20 Hz.
- Temperature: -40 °C

tensor tester resistivity option: Dynamometer mit angeschlossenem Multimeter. Druckprüfung mit isolierten Klemmen und leitfähigem Prüfling. tensor tester resistivity option: Dynamometer mit angeschlossenem Multimeter. Druckprüfung mit isolierten Klemmen und leitfähigem Prüfling. tensor tester resistivity option: Tensor-Check Dynamometer mit optionalem Multimeter: Kompressionsprüfung im Detail.
Test Setup

Test Cycle 

The TensorCheck software allows you to prepare test cycles that include the sequence of operations that the instrument must perform to apply the dynamic cycle intended for the test.
The test cycle includes operations of:
- force adjustment
- displacement adjustment
- temperature regulation (with climatic chamber installed)
- zeroing operations
- control of the production of the curves

Recursive loops can be defined for performing cyclic operations

tensor tester resistivity option: Tensor-Check-Dynamometer mit integriertem Digitalmultimeter zur dynamischen Messung des Widerstands leitfähiger Produkte. Beispiel für die Einstellung eines Zugprüfzyklus. tensor tester resistivity option: Tensor-Check-Dynamometer mit integriertem Digitalmultimeter zur dynamischen Messung des Widerstands leitfähiger Produkte. Beispiel für die Einstellung eines Zugprüfzyklus. tensor tester resistivity option: Tensor-Check-Dynamometer mit Konfiguration für die dynamische Messung des elektrischen Widerstands leitfähiger Produkte. Beispiel für einen Testzyklus für Zugversuche.

Test Curves 

• The curves relating to the tests carried out are shown in different colors to associate them immediately with the relative results.
• By selecting a result, the corresponding curve is automatically highlighted.
• The graphical functions integrated in the programs (scale settings, the number of divisions and zoom) allow you to analyze the curves in detail.
• All the curves are saved in the database together with the test results.

tensor tester resistivity option: Farbige Testkurven: die Ergebnisse auf einen Blick
Farbige Testkurven: die Ergebnisse auf einen Blick

Numerical Results produced 

The TensorCheck software allows you to define for each test method which results you want to calculate.
The specific results related to resistivity measurements are:
- Resistivity at set Force
- Resistivity at set Stress
- Resistivity to set Deformation

tensor tester resistivity option: Dynamometer mit Multimeter für dynamische Widerstandsmessungen an leitfähigen Produkten. Beispiel eines Berichts mit überlagerten Kurven der Ergebnisse verschiedener Produkte.
Dynamometer mit Multimeter für dynamische Widerstandsmessungen an leitfähigen Produkten. Beispiel eines Berichts mit überlagerten Kurven der Ergebnisse verschiedener Produkte.
Management of Test Results

Management of Test Results 

The results and test curves of all the tests carried out are saved in the Gibitre SQL database and are available through the Datagest program.

Datagest is the Laboratory Information Management System (LIMS) which is always installed in combination with all Gibitre instrument-control programs.
The program is the collector for all the test result produced with the instruments connected and permits to manage the common Archives used by the instruments (Product List, Customer List, Tolerance limits, Order List, etc)

tensor tester resistivity option: Datagest: Ein Gehirn für sein Labor
Datagest: Ein Gehirn für sein Labor

Export of test Curves 

It is possible to export the points of the test curves in a .csv file
For each test point, the file reports: Force, Effort, Deformation, Traverse Displacement, Time from Start, Electrical Resistance, Temperature.

tensor tester resistivity option: Datenverwaltungsprogramm Datagest. Das Programm speichert alle Testkurven, die mit den an die Datenbank angeschlossenen Gibitre-Geräten gespeichert wurden. Die Kurven können zur späteren Analyse exportiert werden. Seite zur Anzeige der Kurvenpunkte.
Datenverwaltungsprogramm Datagest. Das Programm speichert alle Testkurven, die mit den an die Datenbank angeschlossenen Gibitre-Geräten gespeichert wurden. Die Kurven können zur späteren Analyse exportiert werden. Seite zur Anzeige der Kurvenpunkte.

Technical specification

Resistance measurement range  10 Micro-Ohm to 120 Mega-Ohm 
Download
General catalogue mail request

News
Call to action
Ask for quotation
a guided way to ask
for a quotation
Mail
info@gibitre.it
The good old e-mail
ready for every season
Phone
+39 035 460146
We welcome your calls Monday through Friday from 8:30 a.m. to 5:30 p.m. in your local time zone.
Newsletter
Subscribe
Stay updated
with the last news
of your sector
Local agent
from: -
See the whole list

In your country
in your language
at your service
Gibitre Instruments S.r.l., Via dell'industria 73, 24126 Bergamo Italia, pec@gibitre-instruments.it P. IVA: IT02827900164 CCIAA REA Bergamo: 326486 | ©2018 - 2026 Gibitre Instruments
Optimist.it
Welcome to the Gibitre Instruments web site
Please chose the preferred Cookie Management.
Benvenuti nel sito Gibitre Instruments
Per continuare scegliete la Gestione dei Cookie che preferite.
Cookies policy
For detailed informations about the use of cookies, please read our
Cookies Management Practice.

Gestione dei Cookies
Per maggiori informazioni sui cookie utilizzati consultate la nostra
Procedura sull'Uso dei Cookies.