Ozone Check - UV
333
Overview 
The instrument Ozone Check - UV is a complete ozone cabinet conforming to ISO 1431 and ASTM D1149 for the measurement of the resistance to cracking under static or dynamic tensile strain of rubber samples or technical articles. The instrument permits to set the test conditions in order to comply with international standard methods.
Close
Close
 
Ozone Check - UV
246
Test Conditions 
The Instruments permits the regulation of:
• Ozone Concentration, between 10 and 500 pphm (UV absorption detector);
• Test temperature, between ambient +5°C and +70°C;
• Air Flow in the Test Chamber, between 1 and 3 air changes/minute.
Close
Close
Ozone Check - UV
347
Key Features 
• Automatic regulation of Ozone Concentration, Temperature and Air Flow.
• Performance of Static or Dynamic tests
• UV-absorption Ozone detector
• Stainless steel cylindrical test chamber for homogeneous ozone distribution
• Generation and shooting down of the Ozone in closed circuit (no exhaust evacuation needed)
• CE labelling
Close
Close
Ozone Check - UV
465
OzoneCheck_10 Software 
The program allows you to:
• Prepare customized test procedures by defining the test parameters (ozone concentration, temperature, number of air changes, duration of the test, concentration of humidity).
• Automatically adjust the instrument according to the parameters of the selected test procedure
• Display the Curves of the ozone concentration, humidity and temperature over time.
• Save test curves and images imported into Gibitre's SQL database.
Close
Close
 
Ozone Check - UV
126
Test report 
Can be printed or saved to pdf in one of the available languages. The format of the Test Report can be customized by the user.
Close
Close
Ozone Check - UV
482
Test Procedures 
The Test procedures define the test conditions relating to:
• Ozone concentration
• Test temperature
• Air flow rate
• Duration of the test
• Relative humidity concentration (optional)

When a test procedure is selected, the instrument adjustment is done completely automatically.

It is possible to copy and modify the predefined Test Procedures or prepare completely customized ones through the Datagest program (installed together with the OzoneCheck program).
Close
Close
 
Ozone Check - UV
622
UV Ozone Detector 
The Ozone concentration measurement device via UV sensor is conforming to ISO 1431-3 and ASTM D4575 standards.
The device:
• Continuously detects the concentration of ozone inside the test chamber
• Performs a self-calibration every 30 seconds by comparing the measurement of the ozonated air with pure air
• Regulates the generation of ozone in the test chamber by means of a PID control ensuring that the test conditions are reached within the times established by the standard and minimizing oscillations.

The device can be supplied with a direct calibration certificate issued by an accredited laboratory.
Close
Close
Ozone Check - UV
529
Test Chamber 
Gibitre Ozone Tester is the only instrument with a cylindrical test chamber with symmetrical air extraction by means of a double-chamber. This unique feature ensures a homogeneous distribution of ozonized air inside the chamber that could not be obtained with a cubic chamber. The chamber is made of stainless steel. The instrument has an inspection windows in the front with two lights on the sides which permit to inspect the samples during the test without need of stopping the test and removing the samples from the chamber.
Close
Close
 
Ozone Check - UV
387
Support for Static test in traction  
• Sample holder for the static strain of 2-4 samples with adjustable distance of the grips.
• Static test piece holder with planetary effect, in compliance with ISO 1431-1 standard. It moves the test pieces over the whole volume of the chamber for a more homogeneous ozone atmosphere exposition.
Up to 64 samples (with 10 mm width) can be tested at the same time with the device.
Close
Close
Ozone Check - UV
77
Support for Static test in traction of Rubber Hoses 
Sample holders for tests on rubber hoses according to ISO 7326-method 1 and 2
Close
Close
Ozone Check - UV
255
Support for dynamic test 
In compliance with ISO 1431, ASTM D1149 and SAE J1401. To be inserted into test chamber for the study of ozone resistance of cured rubber under dynamic conditions (from 3 to 30 cycles/min - 0.05 to 0.5 Hz).
Up to 10 samples can be tested at the same time
Close
Close
Ozone Check - UV
521
Management of Test Results 
The results and test curves of all the tests carried out are saved in the Gibitre SQL database and are available through the Datagest program.

Datagest is the Laboratory Information Management System (LIMS) which is always installed in combination with all Gibitre instrument-control programs.
The program is the collector for all the test result produced with the instruments connected and permits to manage the common Archives used by the instruments (Product List, Customer List, Tolerance limits, Order List, etc)
Close
Close
 
Ozone Check - UV
537
Industry 4.0 integration 
The instrument and the software have been specifically developed to optimize integration with other environments.
The database in SQL format and the Gibitre_Company_Connect program allows you synchronize your company management software with Gibitre database and to speed up the identification of the tests and to use bar-code readers or similar devices.
The automatic logging service permits to send alarm information to the cloud-service platform of Gibitre Instruments in order to optimize the reaction times of the Service Support.
Close
Close
 
Ozone Check - UV
157
Continuation of the Test after unwanted interruption 
The instrument continuously stores the working conditions. After an electrical black out, the user can restart the program and continue the interrupted test.
Close
Close
 
Ozone Check - UV
775
Standard Calibration service for Ozone Cabinet 
The calibration is performed with reference to the requirements of ISO 1431 standard.
The service includes:
• Ordinary maintenance of the instrument
• Complete cleaning of the Ozone Detector with replacement of the internal filters.
• Calibration of the temperature inside the test chamber (40°C).
• Calibration of the Ozone Concentration inside the test chamber (at 50 pphm, 100 pphm, 150 pphm, 200 pphm).
• Calibration of the time for reaching ozone concentration set (NEW)
• Calibration of the relative Humidity inside the chamber at 50% and 75% (Only for instruments with humidity control)
• Final check of the correct working of the instrument.
• Issue and e-mail shipment of the Calibration Certificate with traceability to primary standards.
Close
Close
 
Ozone Check - UV
513
Safety Devices 
• The instrument automatically locks the opening of the instrument when the ozone concentration exceeds 10 pphm to prevent undesired contact with ozonized air.
• The generation and shooting down of the Ozonized airflow is made in closed circuit in order to meet safety requirements and to render an aspiration system unnecessary.
• Safety sensors protect the instrument from excessive temperature and humidity due to incorrect set.
• Safety Push-button
• The instrument is supplied with CE Labelling
Close
Close
 
Ozone Check - UV
290
Hardware requirements 
• Programs can be installed on standard PCs with WINDOWS 7, 8 or 10 OPERATING SYSTEMS.
• The CONNECTION between the instruments and the PC is made using the USB CABLE supplied with the instrument.
• The programs are COMPATIBLE WITH ANTIVIRUS, and other programs installed on the PC.
Close
Close
 
Ozone Check - UV
441
Development and production 
The instrument is totally developed and produced in the plant of Gibitre Instruments in Italy.
All the mechanical parts are produced in the company workshop using modern CNC machines.
Components and sensors from well-known brands are selected in order to ensure the maximum reliability in the measures
Internal trained personnel takes care of all the production stages: assembly, start-up, calibration, packing, shipment and installation.
Close
Close
 
Ozone Check - UV
689
REFERENCES - OZONE CHECK - PC 
BOSCH CHASSIS SYSTEMS INDIA LTD. - INDIA
BREMBO S.P.A. - ITALY
BRIDGESTONE SABANCI LASTIK - TURKEY
C.R.F. CENTRO RICERCHE FIAT SOCIETA - ITALY
C.T.P.C. - CENTRE TECHNIQUE DE PLASTURGIE - MAROC
CATERPILLAR FLUID SYSTEMS S.R.L. - ITALY
CENTRAL INSTITUTE OF ROAD TRANSPORT - INDIA
CHERY AUTOMOBILE CO., LTD. - CHINA
COOPER-STANDARD AUTOMOTIVE ITALY S.P.A. - ITALY
IVECO S.P.A. D.V.D. BOLZANO - ITALY
KATRI (KOREA APPAREL TESTING & RESEARCH - KOREA
LIG-CERISIE S.R.L. - ITALY
PIAGGIO & C. S.P.A. - ITALY
PIRELLI TYRE S.P.A. - ITALY
RELIANCE INDUSTRIES LIMITED - INDIA
RENAULT VEHICULOS INDUSTRIALES S.A. - SPAIN
ROBERT BOSCH (FRANCE) SAS - FRANCE
TOMAS BATA UNIVERZITY - CZECH
Close
Close