Gibitre Flammability Tester
Stainless Steel Cabinet for performing flammability tests of plastic materials, foams and rubber according to UL 94, ASTM D 635 and equivalents


Standards the instrument complies with:   
ASTM D635;   ASTM D3801;   ASTM D4804;   ASTM D4986;   ASTM D5048;   ISO 9772;   ISO 9773;    

Overview 
Instrument for flame resistance test according to UL 94 standard fitted with:
• Stainless steel cabinet with tempered glass viewing window and interior light
• Bunsen burner according to ASTM D 5025 standard
• Flow meter for gas flow regulation
• Support for flame angle set (0°, 20°, 45°)
• Slide for the regulation of the position of the flame
• Sample holder according to the standards with sample position regulation
• Digital thermometer for the measurement of the temperature of the flame
• Digital Timer with 0.1 second resolution for the measurement of test time
• Exhaust fan to remove combustion fumes

Control Panel 
The control panel includes:
• Digital reading of the temperature of the flame
• Timer for the measure of test time
• Button for Start / Stop button for the Timer
• Button for Reset of the Timer
• Button for activation of internal light
• Button for activation of fume aspiration


Gas Flow Adjustment 
The instrument must be connected to a Methan source.

The instrument is equipped with:
• Manometer between between 0 and 25 mBar
• Fluxometer between 0,04-0,36 NL\min with flow regulation knob
• Fluxometer between 0,2-1,3 NL\min with flow regulation knob




Temperature Calibration  
Bunsen burner compliant with ASTM D 5025 equipped with:
• Safety sensor for interruption of gas flow with absent
• Ring for the adjustment of the air / gas mix
• Tiltable support for testing with inclined flame (0 °, 20 °, 45 °)


Temperature Calibration  
The instrument is supplied with:
• Internal Thermometer with thermocouple for 20 mm Test Flame according to ASTM D 5207 standard.
• Ruler for the check of the height of the flame.

The Thermocuple and the ruler are installed inside the chamber.
To test the temperature of the flame, you only need to move the burner under the Thermocouple using the movement knob.


Device for moving the burner in the chamber  
The knob located outside the Cabin allows you to operate the slide and move the burner horizontally inside the chamber.
The device allows the operator to perfectly control the position of the flame under the specimen through the inspection window.




Available Sample Holders 
• Specimen support for Horizontal Burning (HB) test conforming to UL 94, ASTM D 635 and equivalent standards.
• Specimen support for Horizontal Burning of Cellular Polymeric materials (HBF) test conforming to UL 94, ASTM D 4986 and equivalent
• Specimen support for Vertical Burning of Non-rigid Solid Plastics (MVB) test conforming to UL 94 (tests VTM-0, VTM-1 and VTM- 2), ASTM D 4804 and equivalent standards.
• Specimen support for Vertical Burning of Solid Plastics (VB) test conforming to UL 94 (tests V-0, V-1, V-2, 5VA, 5VB), ASTM D 3801 and equivalent standards.
• Specimen support for Vertical Burning (VB) test conforming to JAR 25 853 B standard.


Instrument Structure  
The instrument, completeley made of Stainless Steel, is optimized for being placed on the table of your lab and for the connection to fume evacuation systems.

Development and production 
The instrument is totally developed and produced in the plant of Gibitre Instruments in Italy.
All the mechanical parts are produced in the company workshop using modern CNC machines.
Components and sensors from well-known brands are selected in order to ensure the maximum reliability in the measures
Internal trained personnel takes care of all the production stages: assembly, start-up, calibration, packing, shipment and installation.



Testing Configuration 
 
Types of test that can be performed 
HBF (Horizontal Burning Foamed Material), HB (Horizontal Burning), MVB (Material Vertical Burning), VB (Vertical Burning) 
Test Cabinet 
Stainless steel cabinet with tempered glass viewing window and internal light. 
Burner 
Conforming to ASTM D 5025 standard. With support for flame angle set (0°, 20°, 45°). 
Temperature Control 
Internal Digital thermometer in conformity with ASTM D 5207 standard 
Gas flow Regulation (Methane) 
Integrated Flow meter 
Timer 
Digital Timer with 0.1 sec. resolution. The timer permits to set the flame exposition time. At the end of the count down for flame exposition, the timer permits to count flame extinction time. 
Slide for the regulation of the position 
The slide is controlled by an external handle that permits to move the burner inside the chamber. 
Aspiration of Fumes 
Exhaust fan to remove fumes at the end of the test 
Safety Devices 
 
Safety Devices 
Safety valve for gas flow interruption without flame 
Labelling 
CE Labelling 
Calibration 
 
Calibration 
Calibration Report conforming to UL 94 with traceability to primary standards 


Calibration of test Flame 
Internal Thermometer with thermocouples for 20 mm Test Flame according to ASTM D 5207 standard. 
Technical specifications 
 
Power 
220 VAC ±10%,50 Hz ±3,4 A,single phase, 40 W - 110 VAC ±10%, 60 Hz ±3 on request 
Gas Supply 
The instrument must be connected to a Methan Source or Methan Cylinder 
Internal Dimension 
(W x D x H) 850 x 700 x 812 mm 
External Dimension 
(W x D x H) 925 x 800 x 1235 mm 
Weight 
85 kg 


Gibitre Instruments
Via dell'industria, 18
Bergamo (Italy)
te. +39 035 461146
www.gibitre.it
info@gibitre.it

Gibitre Instruments

Flammability Check

Stainless Steel Cabinet for performing flammability tests of plastic materials, foams and rubber according to UL 94, ASTM D 635 and equivalents




 
Overview 
Instrument for flame resistance test according to UL 94 standard fitted with:
• Stainless steel cabinet with tempered glass viewing window and interior light
• Bunsen burner according to ASTM D 5025 standard
• Flow meter for gas flow regulation
• Support for flame angle set (0°, 20°, 45°)
• Slide for the regulation of the position of the flame
• Sample holder according to the standards with sample position regulation
• Digital thermometer for the measurement of the temperature of the flame
• Digital Timer with 0.1 second resolution for the measurement of test time
• Exhaust fan to remove combustion fumes
Control Panel 
The control panel includes:
• Digital reading of the temperature of the flame
• Timer for the measure of test time
• Button for Start / Stop button for the Timer
• Button for Reset of the Timer
• Button for activation of internal light
• Button for activation of fume aspiration

Gas Flow Adjustment 
The instrument must be connected to a Methan source.

The instrument is equipped with:
• Manometer between between 0 and 25 mBar
• Fluxometer between 0,04-0,36 NL\min with flow regulation knob
• Fluxometer between 0,2-1,3 NL\min with flow regulation knob

 
Temperature Calibration  
Bunsen burner compliant with ASTM D 5025 equipped with:
• Safety sensor for interruption of gas flow with absent
• Ring for the adjustment of the air / gas mix
• Tiltable support for testing with inclined flame (0 °, 20 °, 45 °)

><
  • Il provino viene inserito nell'apposita pinza
  • Il provino viene inserito nell'apposita pinza
Temperature Calibration  
The instrument is supplied with:
• Internal Thermometer with thermocouple for 20 mm Test Flame according to ASTM D 5207 standard.
• Ruler for the check of the height of the flame.

The Thermocuple and the ruler are installed inside the chamber.
To test the temperature of the flame, you only need to move the burner under the Thermocouple using the movement knob.

><
  • Il provino viene inserito nell'apposita pinza
  • Il provino viene inserito nell'apposita pinza
Device for moving the burner in the chamber  
The knob located outside the Cabin allows you to operate the slide and move the burner horizontally inside the chamber.
The device allows the operator to perfectly control the position of the flame under the specimen through the inspection window.

><
  • Il provino viene inserito nell'apposita pinza
  • Il provino viene inserito nell'apposita pinza
Available Sample Holders 
• Specimen support for Horizontal Burning (HB) test conforming to UL 94, ASTM D 635 and equivalent standards.
• Specimen support for Horizontal Burning of Cellular Polymeric materials (HBF) test conforming to UL 94, ASTM D 4986 and equivalent
• Specimen support for Vertical Burning of Non-rigid Solid Plastics (MVB) test conforming to UL 94 (tests VTM-0, VTM-1 and VTM- 2), ASTM D 4804 and equivalent standards.
• Specimen support for Vertical Burning of Solid Plastics (VB) test conforming to UL 94 (tests V-0, V-1, V-2, 5VA, 5VB), ASTM D 3801 and equivalent standards.
• Specimen support for Vertical Burning (VB) test conforming to JAR 25 853 B standard.

><
  • Il provino viene inserito nell'apposita pinza
  • Il provino viene inserito nell'apposita pinza
Instrument Structure  
The instrument, completeley made of Stainless Steel, is optimized for being placed on the table of your lab and for the connection to fume evacuation systems.

><
  • Il provino viene inserito nell'apposita pinza
  • Il provino viene inserito nell'apposita pinza
Development and production 
The instrument is totally developed and produced in the plant of Gibitre Instruments in Italy.
All the mechanical parts are produced in the company workshop using modern CNC machines.
Components and sensors from well-known brands are selected in order to ensure the maximum reliability in the measures
Internal trained personnel takes care of all the production stages: assembly, start-up, calibration, packing, shipment and installation.

Proudly made in Italy
 
Technical specifications
Reference Standards
Standards the instrument complies with:  ISO 9772; ASTM D4986; ISO 9773; ASTM D635; ASTM D3801; ASTM D4804; ASTM D5048;  
Testing Configuration
Types of test that can be performed  HBF (Horizontal Burning Foamed Material), HB (Horizontal Burning), MVB (Material Vertical Burning), VB (Vertical Burning)  Test Cabinet  Stainless steel cabinet with tempered glass viewing window and internal light.  Burner  Conforming to ASTM D 5025 standard. With support for flame angle set (0°, 20°, 45°).  Temperature Control  Internal Digital thermometer in conformity with ASTM D 5207 standard  Gas flow Regulation (Methane)  Integrated Flow meter  Timer  Digital Timer with 0.1 sec. resolution. The timer permits to set the flame exposition time. At the end of the count down for flame exposition, the timer permits to count flame extinction time.  Slide for the regulation of the position  The slide is controlled by an external handle that permits to move the burner inside the chamber.  Aspiration of Fumes  Exhaust fan to remove fumes at the end of the test 
Safety Devices
Safety Devices  Safety valve for gas flow interruption without flame  Labelling  CE Labelling 
Calibration
Calibration  Calibration Report conforming to UL 94 with traceability to primary standards  Calibration of test Flame  Internal Thermometer with thermocouples for 20 mm Test Flame according to ASTM D 5207 standard. 
Technical specifications
Power  220 VAC ±10%,50 Hz ±3,4 A,single phase, 40 W - 110 VAC ±10%, 60 Hz ±3 on request  Gas Supply  The instrument must be connected to a Methan Source or Methan Cylinder  Internal Dimension  (W x D x H) 850 x 700 x 812 mm  External Dimension  (W x D x H) 925 x 800 x 1235 mm  Weight  85 kg 
Download
Product leaflet

General catalogue

Calibration certificate
example
CE certificate
example
 
 
Ask for quotation

Ask for quotation
Mail

Mail
Mail
Phone

Phone
Phone
Local agent


Local agent
FAQ
do you need more information or a quotation?
use the buttons at the bottom of the page.
Cookie policy
Questo sito utilizza i cookies (dati permanenti registrati sul tuo PC) per:
- ricordare la lingua scelta
- ricordare i prodotti preferiti
- suggerire prodotti in funzione delle pagine più visitate
- mantenere aperta la sessione (nella sole aree riservata)

Cliccando su "accetta" autorizzate l'uso dei cookies.

Accetto / Accept

This site uses cookies (permanent data on your PC) for:
- remembering the choosed language
- remembering your favorite products
- suggest other products based upon the most viewed pages
- keep the navigation session open (only in the reserved area)

By ckicking on "accept" you authorize the use of cookies.