© Gibitre Instruments
P.IVA IT02827900164 Web Design Optimist
|
|
Laboratory Press equipped with Cooling system
Laboratory press for the compression moulding of thermoplastic materials equipped with cooling cyrcuit
|
DOWNLOADS:
Leaflet »
|
TECHNICAL CHARACTERISTICS
|
Max platen stroke
|
200 mm
|
|
Max useable platen surface
|
250 mm x 250 mm
|
|
Max closure force
|
20 Tons
|
|
Temperatures
|
From room temperature to 250°C (300°C optional). 0.1°C Resolution
|
|
Platen temperature control
|
Independent temperature control of the plates by means of PID controllers Maximum Temperature difference in the 200x200 mm central area: 2°C
|
|
Touch Screen PLC controller (optional)
|
PLC with touch-screen display. Permits to set: - movements of the moving plate - temperatures of the plates. - activation of cooling and cooling rate (with cooling option) - closure force (with regulation option
|
|
Closure Force Regulator (optional)
|
Special hydraulic controller with pressure regulation valves controlled by the Gibitre Press Control device. Permits to set closure force between 600 and 19600 kg with 10 kg regulation steps.
|
|
Platen cooling
|
Plates with water cooling circuit
|
|
Power supply
|
380 VAC ±10%,50 Hz ±3, 10 A,three-phase -Other on request
|
|
Electrical power
|
6 KW
|
|
Dimensions
|
(Width x Depth x Height) 1100 x 550 x 1650 mm
|
|
Weight
|
520 Kg
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Instrument characteristics The complete design of Gibitre press has been specifically developed to get the best possible results: Mechanical structure with 4 columns (60 mm
Automatic Press Control Gibitre Press Control: PLC with touch-screen display that permits to set the moulding cycle by setting the displacements of the moving plate of the
The cooling system
Cooling is required for moulding of thermoplastics because the moulded part must be brought to solidification temperature before opening the mould.
|
|
SOFTWARE:
The program Gibitre-Press Logger permits to extract data from the PLC controller of the press and to record continuously the test conditions of the machine. The temperature and pressure (if pressure control option is installed) are recorded both graphically and numerically. All the data are stored in a text file which is automatically generated for each working day.
|
|