Rheocheck Profile Oscillating Disk - PC
Oscillating Disk Rheometers controlled by Personal Computer.

STANDARDS:
ISO 3417; ASTM D 2084;
DIN 53 529-4

DOWNLOADS:
Leaflet »
Test Report »

TECHNICAL CHARACTERISTICS

Standards the instrument complies with

ISO 3417; ASTM D 2084; DIN 53 529-4

Numerical Test Data (for each test procedure up to 20 test results can be selected)

Torque Values: MI, ML, M90, MX, MH, PCR (X=customer-defined) S"@ML, TanD@ML, S"@MH, TanD@MH
Scorch Time: tS1, tS2, tSX (X=customer defined)
Cure Time: t90, tX, tML, tMH, tPCR, tRX (X=customer-defined)
Pressure (optional) PL, PH, tP, MPR, tMPR

Graphic representation

Elastic Torque (S'), Viscose Torque (S"), Complex Torque (S*)Tan-Delta curve, Curing speed, Upper and Lower test chamber temperature

Torque Unit

dNm or lbf.in.

Oscillation frequency

100 cycles /minute (1,7 ±0,1 Hz)

Oscillation Angle

1 °,3 °,5 °

Temperature

50 ÷ 230 °C - Resolution 0.1 °C

Power Supply

220 VAC ±10%,50 Hz ±3,4 A,single phase -Other on request

Power

600 Watt

Compressed air

6 bar

Dimensions of instrument

(Width x Depth x Height) 870 x 710 x 1380 mm

Weight

180 Kg

Calibration

Certificate with traceability to primary standard
Torque calibration spring for instrument verification supplied with the device

Pressure Sensor (optional)

Resolution 0.1 bar, Scale base 200 bar

Personal computer

Minimum Configuration: Pentium IV 512 MB RAM
Compatible operating Systems: Windows 2000, NT, XP, Vista
Connection to the instrument with one serial or USB port

Software usage Languages

Italian, English, French, Spanish, German, Portuguese, Russian, Chinese

Overview
Gibitre OD Rheometer measures the cure characteristics of a rubber compound in conformity with the international standards.
The measure of the

Instrument Characteristics
Easily accessible test chamber with transparent safety panel and safety lock.
Test chamber in compliance with international standards.
Direct test

Software & Accessories
SOFTWARE
Graphic representation of the
following curves: Elastic (S’), Viscous
(S"), Complex (S*), Curing Speed, Tan-Delta, upper and lower test

SOFTWARE:
Main Page
All necessary information is displayed on the page: Test Status, Test Identification, Graphs, Tolerance limits, previous test results,

. . . . .