Gibitre Instruments
Company
Rubber testing
Plastic testing
Software
Services
Contacts
News
Distributors
Links
Customers Area
Agents Area
Languages
Home

Rubber Testing

Rheology

Rheometers

 

 
       

© Gibitre Instruments
P.IVA IT02827900164
Web Design Optimist

Rheocheck Profile Moving Die - PC
Moving Die (MD) Rheometer controlled by Personal Computer.

STANDARDS:
ISO 6502; ASTM D 6204;
DIN 53 529-3

DOWNLOADS:
Leaflet »
Test Report »
Detailed Presentation »
More.. »

TECHNICAL CHARACTERISTICS

Standards the instrument complies with

ISO 6502; ASTM D 5289, 6204; DIN 53 529-3

Numerical Test Data (for each test procedure up to 20 test results can be selected)

Torque Values: MI, ML, M90, MX, MH, PCR, S’’@ML, S"@MH, TanD@ML, TanD@MH, G’@ML, G’@MH, G’’@ML, G’’@MH (X=customer-defined)
Scorch Time: tS1, tS2, tSX (X=customer defined)
Cure Time: t90, tX, tML, tMH, tPCR, tRX (X=customer-defined)

Graphic representation

Elastic Torque (S'), Viscose Torque (S"), Complex Torque (S*)Tan-Delta curve, storage shear Modulus (G’), loss shear Modulus (G’’), Curing speed, Upper and Lower test chamber temperature

Units

Torque: dNm or lbf.in.
Time: minutes and seconds, minutes and hundredths of minutes, seconds
Temperature: °C, °F

Oscillation frequency

100 cycles /minute (1,7 ±0,1 Hz)

Oscillation Angle

0.5°, 1°, 3°

Temperature

50 ÷ 210 °C - Resolution 0.1 °C

Power Supply

220 VAC ±10%,50 Hz ±3,4 A, single phase -Other on request. Current stabilizer integrated in the instrument.

Power

600 Watt

Compressed air

6 bar (compressed air treatment and regulation unit is included)

Dimensions of instrument

(Width x Depth x Height) 870 x 710 x 1380 mm

Weight

180 Kg

Calibration

Certificate with traceability to primary standard
Torque calibration spring for instrument verification supplied with the device

Personal computer

Minimum Configuration: Pentium IV 1 GB RAM
Compatible operating Systems: Windows NT, XP, Vista, 7 (64 bit)
Connection to the instrument with USB port

Software usage Languages

Italian, English, French, Spanish, German, Portuguese, Russian, Chinese, Japanese, Turkish, Polish

Overview
Gibitre MD Rheometer measures the cure characteristics of a rubber compound in conformity with the international standards.
The measure of the vulca

Instrument Characteristics
Pressurized Testing chamber
Torque measurement reaction transducer positioned in the upper test chamber to minimize the influence of friction and vib

Gibitre-RheoCheck Software
Graphic representation of the following curves: Elastic (S’), Viscous (S’’), Complex (S*), storage shear Modulus (G’), loss shear Modulus
(G’’),

SOFTWARE:
Main Page
All necessary information is displayed on the page: Test Status, Test Identification, Graphs, Tolerance limits, previous test results,